CODS - Journal of Dentistry

Register      Login

VOLUME 7 , ISSUE 2 ( July-December, 2015 ) > List of Articles

RESEARCH ARTICLE

Effect of UV disinfection on dimensional stability and infection control of elastomeric impression materials

Neha Hajira, Ashwini Wadhwani, G. Vinaya Kumar

Citation Information : Hajira N, Wadhwani A, Kumar GV. Effect of UV disinfection on dimensional stability and infection control of elastomeric impression materials. CODS J Dent 2015; 7 (2):60-63.

DOI: 10.5005/cods-7-2-60

License: CC BY-NC-ND 3.0

Published Online: 01-09-2016

Copyright Statement:  Copyright © 2015; The Author(s).


Abstract

How to cite this article

Vinaya Kumar G, Wadhwani A, Hajira N. Effect of UV disinfection on dimensional stability and infection control of elastomeric impression materials.

CODS J Dent 2015;7:60-63.


PDF Share
  1. Effect of disinfectant agents on dimensional stability of elastomeric impression materials. J Prosthet Dent. 1999;81:621-624.
  2. An in vitro study on the dimensional stability of a vinyl polyether silicone impression material over a prolonged storage period. J Prosthet Dent. 2013 Mar;109(3):172-8.
  3. Antibacterial activity, surface roughness, flexural strength, and solubility of conventional luting cements containing chlorhexidinediacetate/cetrimide mixtures. J Prosthet Dent. 2013 Aug;110(2):107-15
  4. Antimicrobial activities of dental impression materials. Dent Mater. 1998 Nov;14(6):399-404.
  5. Dent Mater. 2006 Sep;22(9):799-803.
  6. Electron beam irradiation of dental composites. Dent Mater. 2005 Sep;21(9):804-10.
  7. Dent Mater. 2004 Feb;20(2):133-41.
  8. Dent Mater. 2004 Jul;20(6):565-9.
  9. Discoloration of facing and restorative composites by UV-irradiation and staining food. Dent Mater. 2006 Jan;22(1):63-8.
  10. An in-vitro study of the sterilization of titanium dental implants using low intensity UV-radiation. Dent Mater. 2005 Aug;21(8):756-60.
  11. Dynamic ultraviolet sterilization of different implant types. Int J Oral Maxillofac Implants. 1990;5(2):117-25.
  12. Evaluation of an ultraviolet disinfection unit. J Prosthet Dent. 1987 Nov;58(5):650-4.
  13. Evaluation of denture base resin after disinfection method using reactive oxygen species (ROS). Dent Mater J. 2012;31(3):443-8.
  14. The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials. J Oral Sci. 2008 Dec;50(4):441-6.
  15. J Indian Prosthodont Soc. 2010 Mar;10(1):41-7.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.